Home / Products and
Services / Stamping Press Products / Press Tonnage Monitors / LoadGard RLG-2
LoadGard RLG-2
Two Channel Force Monitor Automatic Load Monitor with Selectable Alarm Functions

Features of the RLG-2:
-
Two channels, Strain Gage input
-
24 volt DC or 110 volt AC power input
-
Three selectable alarming methods:
-High - Low Trend
-Adaptive Learn
-Area Under the Curve
|
-
Built-in press capacity alarms
-
Easy to use, no programming
-
Small, rugged enclosure
-
Backed by over 35 years of Helm experience
|
Adaptive Learn
|

Adaptive learn alarming is ideal for high speed forming
operations where changes in material thickness, hardness or temper happens very
quickly. This alarming option continuously adjusts the upper and lower control
limits based on the average tonnage developed during the previous 100 machine
strokes. Selecting this Adaptive learning technique will guarantee you the
tightest alarm bandwidth without nuisance shutdowns.
|
Area Under the Curve
Utilizing Helm signature analysis techniques, this alarming method
continuously monitors the energy curve that is generated as each part is formed.
If any area of the forming signature changes, machine shutdown is initiated.
Applications for area under the curve alarming include presses performing deep
draw or stretch forming operations and machines using nitrogen die cylinders.
This feature provides accurate thru-the-stroke tonnage monitoring without the
need of a resolver. |
Trend
The Trend alarm option allows you to select the "quality window" the process
must operate within. These limits are selectable from plus or minus 5% to 45%,
in 5% increments. Once the forming process begins, the Trend alarms are
automatically set above and below the benchmark tonnage value. Machine shutdown
is activated if the forming force varies outside the monitoring range. |
Model RLG-2 24 volt system supplied with mounting bracket

Model RLG-2FL 24 volt system supplied with mounting flange

Model RLG-2AC 115 volt system supplied with mounting bracket

|
Specifications |
|
Number of Channels: |
Two |
|
Power Requirements: |
24 volts DC or 110 volts AC |
|
Sensor Inputs: |
Two Helm 350 ohm Strain Gage sensors |
|
Timing Input: |
24 volt DC (via cam switch prox probe or PLC |
|
Input Connectors: |
Two 5-pin Turck for sensors
One 4-pin Turck for power
One 3-pin Turck for timing |
|
Operating Range: |
Single stroke to 1000 strokes per minute |
|
Output Relays: |
Two independently wired relays provided for capacity
and Trend alarms. Each relay rated at 24 VDC, 0.5 Amp. Note: 110 VAC system
supplied with two 24 volt dry contact relays. |
|
Instrument Gain: |
Selectable from 50 - 7000 |
|
A to D: |
12 bit |
|
A to D Sample Rate: |
100 microseconds |
|
Display Resolution: |
Up to 0.1% full scale |
|
Overall Accuracy: |
1% full scale |
Ordering Information
System Options
RLG-2 24 volt system with mounting
bracket
RLG-2FL 24 volt system with flange enclosure
RLG-2AC 110 volt system with mounting bracket
Note: All systems supplied with five inter-connect cables as follows.
(1) 24 VDC or 80-250 VAC power
(2) 24 VDC I/O
(2) HT-400 sensor input
Sensor Kits
L2-DBS Two sensor kits for drill/tap mounting
OR
L2-WBS Two sensor kits for weld/pad mounting
Sensor Kit Components
DF-400 Drill guide
WP-400 Weld pad (set)
WTS-1 Cover with terminal strip
WF-400 Weld fixture
T-21 Protection box


|